Clariance-SAS recalls Brand Name
- Published
- 22 Apr 2026
- Units affected
- 511
- Agency
- FDA
- Country
- United States
The hazard
Due to a quality issue regarding the presence of burr on the finished cervical plate product.
Classification: Class II — this product may cause temporary or medically reversible health problems; the chance of serious harm is remote.
What to do
Contact your doctor, clinic or the device maker to find out if your device is affected and what to do next. Do not stop using a life-supporting device without medical advice.
- Check the model and lot or serial number on the device label.
- Speak to your doctor or the clinic that supplied the device before stopping use.
Product details
Brand Name: Elegance¿ Anterior Cervical Plate Product Name: ELEGANCE 1 LEVEL CERVICAL PLATE, ELEGANCE 2 LEVEL CERVICAL PLATE, ELEGANCE 3 LEVEL CERVICAL PLATE, ELEGANCE 4 LEVEL CERVICAL PLATE Model/Catalog Number: See Excel sheet attached named "FDA 5072 Product Information" Software Version: Not applicable Product Description: The Elegance¿Anterior Cervical plate is designed for use as a cervical plate system. It has a shape which restores the intervertebral height and lordosis. The Elegance¿ Anterior Cervical plate consists in a variety of shapes and sizes of cervical plates with rounded corners, featuring bone screw s holes, locking systems and bone screws. The plates go from one (1) to five (5) levels, and the screws are selfdrilling or self- tapping, and fixed or variable. The fixation is provided by the bone screws inserted into the vertebral body by means of an anterior approach. The Elegance¿plates, as well as the bone screws, are made of compliant ASTM F136 Titanium alloy. It is essential to insert the implants with the instrumentation specifically designed for this purpose. For more description of the instrumentation, read the technical documentation associated to the Elegance¿ Anterior Cervical plate. Detailed information concerning the surgical technique of the Elegance¿Anterior Cervical plate is available upon request, please contact CLARIANCE or its local representative.
- Brand / company
- Clariance-SAS
- Codes / lots
- Lot Code: See Excel sheet attached named "FDA 5072 Product Information" See Spreadsheet attached named "FDA 5072 Product Quantity Distributed" Catalog Number: 53430108 (ELEGANCE 1 LEVEL CERVICAL PLATE 8MM) UDI-DI code: 03700780644353 Lot Numbers: PC03X R879X Catalog Number: 53430110 (ELEGANCE 1 LEVEL CERVICAL PLATE 10MM) UDI-DI code: 03700780644353 Lot Numbers: P758X RAA2X R825X R902X Catalog Number: 53430111 (ELEGANCE 1 LEVEL CERVICAL PLATE 11MM) UDI-DI code: 03700780644384 Lot Numbers: R194X RAA1X Catalog Number: 53430112 (ELEGANCE 1 LEVEL CERVICAL PLATE 12MM) UDI-DI code: 03700780644391 Lot Numbers: R195X RAB2X Catalog Number: 53430113 (ELEGANCE 1 LEVEL CERVICAL PLATE 13MM) UDI-DI code: 03700780644407 Lot Numbers: R196X R197X R584X RA81X Catalog Number: 53430114 (ELEGANCE 1 LEVEL CERVICAL PLATE 14MM) UDI-DI code: 03700780644414 Lot Number: R585X Catalog Number: 53430116 (ELEGANCE 1 LEVEL CERVICAL PLATE 16MM) UDI-DI code: 03700780644438 Lot Number: R586X Catalog Number: 53430120 (ELEGANCE 1 LEVEL CERVICAL PLATE 20MM) UDI-DI code: 03700780644452 Lot Number: R182X Catalog Number: 53430220 (ELEGANCE 2 LEVEL CERVICAL PLATE 20MM) UDI-DI code: 03700780644452 Lot Numbers: R587X RAA0X Ca
- Distribution
- U.S. Nationwide distribution in the states of CA, IL, NY and TX.
- Recall status
- Ongoing
Source: U.S. Food and Drug Administration, published 22 Apr 2026. CheckMyRecalls reproduces the official notice in summary; always confirm the details with the original notice.