Medical devices recalls
2,678 recalls since January 2025 from Health Canada, FDA, newest first. Last notice 19 Nov 2026.
Page 31 of 54
- Medistim Asa recalls Brand NameFDAPrinter Support Module (PSM) may be subject to insufficient soldering, which may cause loosening of the wires and system to shut down. Affected…
- Surgical Theater Inc recalls SuRgical Planner (SRP) and 6 moreFDAA software anomaly, under specific conditions when large rotational alignment values are applied in 2D Image Fusion, may lead to misalignment of any…
- DAYE (ANNE'S DAY LTD) recalls Refill 3 Month All in One Bundle and 28 moreFDAProduct lacks 510(k) clearance.
- Canon Medical System, USA, INC. recalls VANTAGE GALAN 3TFDAAffected system contains components that do not meet the required distance between electrodes for compliance with the IEC 60601-1 standard for…
- Alcon Research LLC recalls Alcon PRECISION1 One-Day Contact LensesFDAPotential for a weak seal in some units resulting in compromise in sterility.
- Microgenics Corporation recalls Thermo scientific MAS Omni CARDIOFDAThe firm received complaints from customers reporting vial-to-vial variability when using the control with high sensitivity Troponin I assays. This…
- Trividia Health, Inc. recalls Good Neighbor PharmacyFDAManufacturing defect causing LCD display issues with missing or partial segments (ghosting) that can result in misreading glucose values,…
- IMPRIS Imaging Inc recalls IMRIS Operating SuiteFDAThere is a potential safety issue associated with the magnet venting paths of the Siemens 3 Tesla MRI system within your IMRIS Operating Suite.…
- Rocket® Seldinger Chest Drain KitHealth CanadaLabelling and packaging
- Olympus Medical Single Use Electrosurgical Snare SD-400Health CanadaSterility
- BK Medical Ultrasound SystemsHealth CanadaLabelling and packaging
- BD Alaris™ Pump ModuleHealth CanadaPerformance
- Instrumentarium Nagahara chopperHealth CanadaPerformance
- SEDECAL SA recalls MobileDiagnost wDR 2.2 and 25 moreFDASedecal sent an email to its consignees to remind the users that the equipment is not water-resistant and must be cleaned strictly according to the…
- Home Health US, Incorporated recalls One Step Sterile Lancet for Single Use (3 sizes)FDADue to incorrect/lack of Unique Device Identifier (UDI) codes.
- Tandem Diabetes Care, Inc. recalls t:slim X2 insulin pump with Interoperable TechnologyFDAA software defect in versions 7.9.0.1 and 7.10.1 of the pump software for Tandem t:slim X2 and version 7.9.0.1 of the Tandem Mobi pump with…
- Becton Dickinson & Co. recalls BD EpiCenter Microbiology Data Management System and 4 moreFDAProduct service credentials used by some BD technical support teams to access certain BD products were accessed by an unauthorized actor. Until…
- Abiomed, Inc. recalls Automated Impella Controller (AIC) labeled as the following with co…FDAPotential for Automated Impella Controller (AIC) purge pressure issues due to purge retainer failures.
- Cardinal Health 200, LLC recalls Salem Sump PVC TubesFDAFirm has received complaints regarding Anti-Reflux Valve (ARV) breakage due to excessive force during use. Firm is providing additional guidance for…
- GE Medical Systems, LLC recalls MAC VU360 Acquisition Trunk Cable and Module HolderFDAIf a user incorrectly places the Acquisition Module into the Acquisition Module Holder, it can result in excessive bending and wear of the…
- B BRAUN MEDICAL INC recalls Brand NameFDAThe potential for micro-air bubbles observed in the bloodline and air-in-line alarms due to damaged arterial and venous patient connectors.
- Baxter Healthcare Corporation recalls Oral Probe (Product code 02893-000)FDAAffected oral/axillary probes were inadvertently programmed with the rectal probe configuration. Affected probes will potentially display a lower…
- Beckman Coulter, Inc. recalls DxI 9000 Access Immunoassay Analyzer and 1 moreFDABeckman Coulter has confirmed a software anomaly on DxI 9000 Access Immunoassay Analyzer and the DxC 500i Clinical Analyzer that may prevent correct…
- Wipro GE Healthcare Private Ltd. recalls GE Healthcare Carescape Central Station (CSCS) V3 MAS800 Desktop wi…FDACarescape Central Station (CSCS), software version V3.0.5, can cause the system to enter a continuous reboot cycle. If this occurs, a loss of…
- GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING recalls Elscint SPX6 and 13 moreFDAGE HealthCare has become aware that certain Nuclear Medicine systems that are past the End of Guaranteed Service could have been transported or…
- HeartSine Technologies Ltd recalls HeartSine Pad-PakFDADue to customer complaints, defibrillator pads may contain damage pins that disrupt the mechanical fit and electrical contact.
- UIH Technologies LLC recalls Shanghai United Imaging Healthcare Co.FDAThird-party outer covers can become trapped between patient table and gantry, causing mechanical interference during table movement.
- Biomet, Inc. recalls BIOMET ZipTightFDAThere is a potential for a missing slotted button assembly in one lot of ZipTight, Acute AC Joint Implant, Single Ziploop
- Medline Industries, LP recalls Excelsior MedicalFDAMedline has identified a limited quantity of saline IV flush syringes that may not meet the required concentration of sodium chloride.
- Theken Companies LLC recalls iNSitu Bipolar Hip SystemFDADownstream recall for RES 97605, BioPro femoral components. Product failed transit testing. Impacted product may have potential issues with sterile…
- CPM Medical Consultants, LLC. recalls Fuse ULTRA Foot Plating System Instructions for UseFDAInstructions for use for a foot plating system is being updated to remove the second option of requirements for sterilization which was 3 minutes…
- PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. recalls Zenition 50FDAOver time some systems may experience loss of imaging functionality and/or poor image quality due to potential corrosion of the Image Intensifier…
- Synthes (USA) Products LLC recalls LOW PROF LCKNG SCREWFDAAlthough the etched length on the screw is correct, the length marked on the external packaging is incorrect. Specifically, 42mm screws were…
- ICU Medical, Inc. recalls IV Administration setsFDAIV Gravity burette administration set burette component is missing an internal shutoff valve intended to stop fluid flow, which if used may result…
- LeMaitre Vascular, Inc. recalls Artegraft¿ Collagen Vascular GraftFDAThe device was incorrectly packed in the wrong size labeled outer packaging.
- Digital Diagnostic Mobile X-Ray System GM85Health CanadaPerformance
- Schiller EASY PULSE®Health CanadaPerformance
- IntelePACS®Health CanadaPerformance
- ShockPulse Lithotripsy TransducerHealth CanadaPerformance
- Sysmex DI-60™ Main UnitHealth CanadaPerformance
- MAMMOMAT InspirationHealth CanadaDevice compatibility
- Xpert® CT/NGHealth CanadaPerformance
- B. Braun IV Administration Sets & Infusomat® Space® Administration SetsHealth CanadaPerformance
- CARESCAPE B450Health CanadaPerformance
- Automated Impella® ControllerHealth CanadaPerformance
- CARESCAPE ONE and Portrait VSMHealth CanadaPerformance
- BD™ Luer Tip CapsHealth CanadaDevice compatibility
- Codman® Disposable PerforatorHealth CanadaPerformance
- SimplyGo Mini Battery KitHealth CanadaPerformance
- Axonics SNM System® - Tined LeadHealth CanadaPerformance